Shared spaces

Balcony

Owner requirements alignedDesign development pendingUpdated 16 August 2026

Area on the plan

Balcony

Existing Balcony footprint highlighted.

Use this drawing for spatial context only. Dimensions and site conditions must still be verified before design or construction.

Open the complete redacted plan
Redacted apartment floor plan with the Balcony highlighted
Existing Balcony footprint highlighted.

After the merge

What remains before design sign-off

The owner brief is aligned. These remaining items require interior-designer input, specialist confirmation, measurements or later selections; they do not reopen the completed brainstorm and merge.

Context and Design Intent

Create a calm, welcoming and reconfigurable balcony centred on the existing digital piano, reading and relaxation while retaining capacity for children's play, useful ventilation, weather resilience, easy maintenance and a barrier-free connection to the living and dining area.

This file is the authoritative requirements record for the Balcony. It preserves the valid initial requirements and merges the two independently completed owner brainstorms without selecting between differing preferences.

Non-Negotiables

BAL-NN-001 — Preserve power and a viable provisional balcony position for the massage chair without committing the final furniture layout to it.
BAL-NN-005 — Agreed: Reuse the existing Medeli SP-C120 digital piano as the primary balcony equipment item and provide dedicated power, bench and player clearance, cable access and environmental protection.
BAL-NN-006 — Agreed: Provide a level, barrier-free transition between the living area and balcony without compromising rainwater containment or drainage.
BAL-NN-007 — Agreed: Use a fully enclosed but openable window system around the curved perimeter, with compatible insect screening and adjustable internal curtains or blinds.
BAL-NN-008 — Agreed: Retain effective drainage and use weather-resistant, wet-cleanable, easy-maintenance finishes that do not allow water to enter the adjoining interior.
BAL-NN-009 — Yasmin: Box the existing water or plumbing pipe neatly into the design while preserving an accessible panel for future HIP work.
BAL-NN-010 — Fahmi: Use child-safe openable windows and securely restrain any tall furniture against tipping.
BAL-NN-036 — Agreed: Provide an additional balcony water point. Route the associated piping discreetly and neatly, while keeping isolation, inspection and future maintenance access practical.

Strongly Preferred

BAL-SP-002 — Agreed: Retain safe, flexible capacity for children's play together with good airflow; this need not become a fixed toy-storage or dedicated play-zone installation.
BAL-SP-003 — Agreed: Use weather-resistant, easy-maintenance finishes with suitable drainage.
BAL-SP-011 — Agreed: Provide layered, separately controlled warm mood lighting and brighter general lighting, coordinated with the adjoining living and dining areas.
BAL-SP-012 — Agreed: Provide sufficient power for the piano, massage-chair provision and small reading-related devices without relying on one general-use socket.
BAL-SP-013 — Agreed: Provide a ceiling fan in accordance with the whole-home ceiling-fan requirement, subject to safe structural coordination and proportionate visual integration.
BAL-SP-014 — Agreed: Preserve useful natural ventilation when the enclosure is open and protection from wind-driven rain, external noise and seasonal sunlight when closed.
BAL-SP-037 — Agreed: Keep the furniture layout reconfigurable rather than fixing it permanently around the piano, massage chair and reading zone.
BAL-SP-038 — Agreed: Use a simple freestanding bookshelf rather than a tall fixed or multipurpose storage installation. A glass-door model is preferred; confirm the final dimensions and model during furniture selection.

Decisions Outstanding

None currently.

Differences Requiring Joint Discussion

None unresolved.

Resolved joint decisions

BAL-DIFF-001 / BAL-DO-024 — Resolved 16 August 2026: Fahmi and Yasmin jointly agreed to retain flexible children's play capacity.
BAL-DIFF-002 / BAL-DO-004 — Resolved 16 August 2026: jointly agreed to provide the additional water point with discreet, maintainable piping, recorded under BAL-NN-036.
BAL-DIFF-003 / BAL-DO-025 — Resolved 16 August 2026: jointly agreed to preserve only power and a viable provisional massage-chair position, recorded under BAL-NN-001.
BAL-DIFF-004 / BAL-DO-026 — Resolved 16 August 2026: jointly agreed that the furniture layout will remain reconfigurable, recorded under BAL-SP-037.
BAL-DIFF-005 / BAL-DO-027 — Resolved 16 August 2026: jointly agreed on a simple freestanding bookshelf rather than tall multipurpose storage, recorded under BAL-SP-038.
Detailed requirements and coordination

Provisional Ideas

BAL-P-015 — Fahmi: Preserve the option of replacing the digital piano with an upright acoustic piano if future piano development warrants it.
BAL-P-016 — Fahmi: Consider solar-control film if glare reduction is worthwhile and it remains compatible with the selected windows, curtains and insect screens.
BAL-P-018 — Yasmin: Use one indoor plant or flower pot.

Subject to Feasibility

BAL-SF-019 — Confirm the complete piano setup dimensions and protect it from direct sun, excessive heat, dust, humidity and rain exposure; assess floor loading and environmental conditions before preserving space for a future acoustic piano.
BAL-SF-020 — Verify the location, condition and capacity of the balcony floor trap and demonstrate suitable falls, wet-washing discharge and water containment.
BAL-SF-021 — Test whether stacking or folding window panels and retractable insect screens can operate safely around the curved perimeter; casement windows remain an acceptable fallback if stacking is infeasible.
BAL-SF-022 — Confirm the ceiling can safely accommodate the fan without conflicting with the piano, lighting, curtain tracks, windows or intended visual character.
BAL-SF-023 — Assess wind-driven rain, seasonal sun, external noise, humidity and privacy at the unit before finalising the enclosure and finishes.

Attributed Owner Positions

These positions remain attributed and are not jointly agreed requirements unless recorded otherwise later.

Fahmi

BAL-FP-028 — Preserve open central floor space and arrange the piano, possible massage chair and possible tall bookshelf around the perimeter.
BAL-FP-029 — Different balcony tiles may create visual distinction provided the transition remains level and trip-free.
BAL-FP-030 — External privacy is not presently a major concern, subject to site confirmation.
BAL-FP-031 — Allow some plants if they do not compromise circulation, safety, piano protection or wet cleaning.

Yasmin

BAL-YP-032 — Make the balcony feel calm, welcoming and visually distinctive when viewed from the living area.
BAL-YP-033 — Prefer timber-look tiles, avoid vinyl and grout-heavy surfaces, and keep the space simple and uncluttered.
BAL-YP-034 — Position the massage chair facing inward, sheltered from direct sun and rain.
BAL-YP-035 — Use a cohesive but distinct style, one indoor plant and no additional storage beyond the reading bookshelf.

Questions for the Interior Designer

Show a dimensioned, reconfigurable layout with the complete piano setup, provisional massage-chair position, freestanding bookshelf, children's play capacity and clear circulation.
Demonstrate how the level transition, enclosure, floor falls, floor trap and wet washing will prevent water entering the interior.
Compare safe curved-perimeter window systems for full opening, rain protection, insect screening, acoustic performance and curtain integration.
Show how the existing pipe can be boxed neatly while preserving accessible future-HIP maintenance.
Show the additional water point and discreet piping route, including isolation and maintenance access.
Confirm fan structure, lighting, socket positions, sunlight control and piano environmental protection.
Provide site observations for sun, wind-driven rain, noise, humidity and privacy before the window and finish strategy is frozen.

Whole-Home Coordination

Apply the ceiling-fan requirement and coordinated electrical-service principles in `10 - Requirements/01 - Whole-Home Systems Requirements.md`.
Coordinate the balcony enclosure, curtains and visual connection with the Living and Dining masters.
Preserve the existing water or plumbing pipe and future-HIP access; provide the jointly agreed additional user water point with discreet, maintainable piping.